Monthly Release Webinar
Learn About New Features in First Due
Each month, we’ll cover the latest First Due releases in a dedicated webinar. Join us to review new features, product updates, and enhancements designed to help your agency get the most out of First Due.
Register for the Webinar
Improved Signature Capture Experience on Tablets (Feature Enhancement)
- What - The signature capture area has been enlarged, and the signature modal has been redesigned for tablet users within ePCR. The updated layout maximizes available screen space in both portrait and landscape orientations, repositions action buttons, and maintains access to signature reasons and associated legal disclosure text.
- Why - The previous signature capture area provided limited signing space, particularly when tablets were used in portrait orientation. Additionally, the placement of action buttons increased the potential for accidental selections when a signer rested their palm on the screen. These improvements provide a more comfortable, intuitive, and reliable signature capture experience in the field.
- How
Open an ePCR on a tablet device and navigate to the applicable Signature section.
Open the Signature Modal to access the redesigned layout.
The enlarged Signature Capture Area is positioned at the bottom of the screen, maximizing available signing space.
The Cancel and Save buttons are positioned at the top of the modal to help prevent accidental selections while signing.
The layout makes better use of available screen space in both Portrait and Landscape orientations.
Select or update the Reason for Signature directly within the modal, as needed.
The associated Legal Disclosure Text updates based on the selected reason and remains accessible within the modal.
Have the patient or crew member sign within the enlarged Signature Capture Area using their finger or stylus.
If additional signing space is needed, rotate the tablet. The layout adjusts to the new orientation without losing the signature in progress.
Select Save at the top of the modal to save the signature, or Cancel to discard it.
- Use Case - A medic documenting a patient refusal hands a tablet to the patient to obtain their signature. The patient can review the applicable legal disclosure and comfortably sign within the enlarged capture area without accidentally selecting Cancel or Save while resting their palm on the device. The improved layout helps streamline signature collection, reduce unnecessary re-signing, and support more efficient ePCR documentation in the field.
Streamlined Signature Status Capture in ePCR Signature Blocks (Feature Enhancement)
- What – The No Signature Reason toggle has been removed from ePCR signature blocks, and the associated field has been renamed Signature Status. The field now automatically populates and locks when a signature is captured. Additionally, inline guidance messaging and a signature status badge within the signature modal header provide greater visibility into the current status and available actions.
- Why – This enhancement simplifies the signature documentation process by eliminating unnecessary manual steps and preventing conflicting signature entries. These improvements promote consistent documentation, improve data accuracy, and reduce friction for providers completing patient care reports.
- How –
Within an ePCR, access the Signatures section and open the applicable signature block.
When a signature is captured, Signature Status automatically populates as Signed or Signed Not Patient, depending on the signature block's existing patient designation. The field is then locked to prevent conflicting entries.
If a signature cannot be obtained, select the applicable reason directly from the Signature Status dropdown without enabling a separate toggle.
Selecting any standard or agency-customized not-signed reason automatically disables the Signature Graphic and Signature Date/Time fields.
To change the status of a captured signature, use the Clear control, when available, to remove the signature and reset Signature Status to blank.
To capture a signature after selecting a not-signed reason, clear the Signature Status field to re-enable signature capture and date/time entry.
Inline guidance messaging explains why fields are disabled and what actions are required to make corrections.
The signature modal header displays a badge reflecting the current Signature Status value or Not Signed when the field is blank. The badge updates immediately without requiring a save or reload.
This enhancement applies to both web and mobile workflows.
Note: The ability to clear a captured signature remains dependent on the existing Signature Setup configuration. NEMSIS XML exports and printed PDF output remain unchanged.
Availability: This enhancement will be enabled globally following the customer notification period. No agency-level configuration is required.
- Use Case – During patient care documentation, an EMS provider captures a patient's signature, and the system automatically records Signed without requiring additional manual input. If a patient refuses to sign, the provider can select the appropriate not-signed reason, automatically preventing conflicting signature entries. A supervisor reviewing the ePCR can quickly verify the recorded signature status using the badge within the signature modal header.
Conditional Custom Schematron Validation Based on Incident Location (New Enhancement)
- What – Agencies can now configure EMS custom Schematron files to apply validation rules based on an incident's location using State, County, and/or ZIP Code criteria. This enhancement allows multiple jurisdiction-specific Schematron files to remain active simultaneously while ensuring only applicable custom validation rules are enforced for each ePCR. National and active State Schematron validation remain unchanged.
- Why – EMS agencies operating across multiple jurisdictions must comply with varying regional reporting and validation requirements. Location-based Schematron validation improves regulatory compliance, reduces irrelevant validation errors, and ensures providers meet the reporting requirements specific to the jurisdiction in which an incident occurs.
- How –
Navigate to EMS Setup > Custom Schematron Files.
Create a new EMS custom Schematron file or edit an existing file.
Define the applicable Location Jurisdiction using one or more of the following criteria:
State – Applies validation based on the incident's state.
County – Applies validation based on the incident's county.
ZIP Code – Applies validation based on the incident's ZIP Code, allowing for more specific jurisdictional coverage.
When multiple location criteria are configured on a single file, all configured criteria must match the incident's location for the Schematron to apply.
Save the configuration to immediately apply location-based validation.
When an incident matches multiple active custom Schematron files, all matching files will apply.
If the incident's location information does not satisfy the configured criteria, the associated location-specific custom Schematron will not apply.
Existing custom Schematron files will retain their current agency-wide validation behavior until edited.
Active files without a configured jurisdiction will display a red row highlight, and a red indicator will appear on the Schematron setup page to prompt administrators to define the applicable jurisdiction.
Jurisdiction configuration is required when creating or editing an EMS custom Schematron file.
Note: This enhancement applies exclusively to EMS-type custom Schematron files. DEM-type custom Schematron files and National and State Schematron validation behavior remain unchanged.
- Use Case – An EMS agency operating across multiple counties can configure separate Local Emergency Medical Services Agency (LEMSA) Schematron files for each jurisdiction. When a provider completes an ePCR, the system automatically applies the custom validation rules associated with the incident's location. If a county is divided between multiple LEMSAs, administrators can use a combination of County and ZIP Code criteria to refine validation coverage. This ensures providers receive relevant validation results, reduces unnecessary documentation corrections, and supports compliance with regional reporting requirements.
Separated Navigation for ePCR, Fire Documentation, and QA/QI (Feature Enhancement)
- What – The main navigation menu has been reorganized to provide dedicated top-level sections for ePCR, Fire Documentation, and QA/QI. Each section retains its associated child tabs, allowing users to access their respective documentation and quality management tools independently.
- Why – Separating these areas into dedicated navigation sections improves usability, reduces navigation complexity, and allows users to quickly locate the tools relevant to their roles and responsibilities. This enhancement creates a more intuitive experience when accessing EMS documentation, fire documentation, and quality assurance workflows.
- How –
Access the application's Main Navigation Menu.
Select ePCR to access EMS patient care reporting and its associated child tabs.
Select Fire Documentation to access fire incident reporting and its associated child tabs.
Select QA/QI to access quality assurance and quality improvement tools and their associated child tabs.
All previously available child tabs remain accessible under their respective parent sections.
Note: This enhancement reorganizes the navigation structure while retaining access to existing functionality.
- Use Case – An agency providing both fire and EMS services can benefit from a more streamlined navigation experience across multiple operational roles. EMS providers can navigate directly to ePCR to complete patient care reports, fire personnel can access Fire Documentation to document fire incidents, and quality assurance personnel can independently access QA/QI to conduct documentation reviews. This separation reduces unnecessary navigation and allows personnel to more efficiently access the tools relevant to their daily responsibilities.
Confirmation Warning When Committing Consumables (Feature Enhancement)
- What – A confirmation dialog has been added when committing individual consumables to prevent unintended inventory updates. When committing multiple consumables using Commit Supplies, users will receive a confirmation displaying the total number of rows being committed before finalizing the action.
- Why – Committing a consumable is an irreversible action that updates inventory and prevents further editing of the committed row. This enhancement provides users with an opportunity to review and confirm their actions, reducing the risk of accidental commits and maintaining accurate inventory records.
-
How –
- Locate the consumable row you wish to commit and select the Commit action.
- A confirmation dialog will appear displaying the following message: "Committing this consumable will update inventory and cannot be undone. Are you sure?"
- Select Commit to confirm the action and update inventory.
- Select Cancel to return without making any changes.
- To commit multiple consumables, select the desired rows and click Commit Supplies.
- Review the number of rows being committed in the confirmation dialog before proceeding.
- Note: Bulk commits require only one confirmation rather than individual confirmations for each selected row.
-
Use Case – While reviewing consumable entries following an incident, a user accidentally selects the commit action on the wrong row. The confirmation dialog allows the user to cancel the action before inventory is updated. When committing multiple consumables, the user can also verify the total number of selected rows before finalizing the action, helping prevent unintended inventory updates and the premature commitment of incomplete entries.
ePCR Consumables and Asset Inventory Integration (New Enhancement)
- What - This enhancement integrates ePCR consumable documentation with Assets inventory management, allowing supplies used during patient care to automatically populate Supply Items Used based on agency-configured procedure mappings. For agencies utilizing Assets, consumable usage can be reconciled against inventory at the appropriate apparatus or storage location, reducing duplicate documentation and manual inventory adjustments. Agencies without Assets can also benefit from the configurable Consumables Catalog and automated procedure-based consumable documentation.
- Why - Documenting clinical procedures and inventory consumption separately creates additional work for providers and increases the potential for missed supply usage, inconsistent reporting, and inaccurate inventory counts. This enhancement streamlines documentation, improves inventory accuracy, and provides greater visibility into supply consumption while minimizing administrative reconciliation and maintaining continuity of patient care documentation.
-
How
- Configure your agency's Consumables Catalog, including Assets-synced and custom consumable items, as applicable.
- Navigate to EMS Setup > Protocols > Treatment Details > Procedure Settings to configure procedure-to-consumable mappings, including size-specific mappings where applicable.
- Document procedures within the ePCR as part of the existing clinical documentation workflow. Associated consumables will automatically populate based on configured mappings.
- Navigate to Billing, Outcomes & External Reporting > Consumables > Supply Items Used to review documented consumables, quantities, inventory sources, and reconciliation statuses.
- Use Add Consumable to manually document custom consumables that were not automatically captured through procedure mappings.
- For agencies utilizing Assets, inventory sources are automatically resolved when sufficient information is available. Providers can resolve exceptions when multiple inventory sources exist or additional information is required.
- During multi-unit responses or ePCR transfers, consumable usage is attributed to the appropriate inventory source rather than automatically defaulting to the transporting apparatus.
- Select Complete to finalize the ePCR and initiate inventory reconciliation for eligible, resolved consumables that have not already been committed.
- Agency-configured completion settings determine whether providers receive a warning or must resolve actionable inventory exceptions before completing the ePCR.
- Note: Consumable documentation remains available offline using locally available configuration. Assets inventory reconciliation requires connectivity, and offline usage is not automatically reconciled upon reconnection.
- Note: Assets system or connectivity failures will not prevent clinical documentation or ePCR completion.
- Use Case - During a multi-unit EMS response, an engine crew establishes an IV using an 18-gauge catheter before transferring patient care to a transporting ambulance. As the procedure is documented in the ePCR, the associated consumable automatically populates Supply Items Used. Additional supplies used by the ambulance crew are documented within the same report, with each consumable attributed to its appropriate inventory source. Upon successful inventory reconciliation, Assets reflects the supplies consumed from each apparatus, allowing agency personnel to monitor inventory levels and identify restocking needs without duplicating documentation.
Automated Export Failure Notifications (New Enhancement)
- What – First Due now supports automated failure notifications for ePCR export endpoints. Agencies can independently configure notifications for each endpoint, including billing platforms, state repositories, and other external integrations, ensuring designated personnel are automatically alerted when an export fails to transmit successfully.
- Why – This enhancement reduces reliance on manual audits and ad hoc reporting to identify export failures. By providing timely visibility into failed transmissions, agencies can proactively address integration issues, minimize billing and revenue cycle delays, and reduce potential compliance risks.
- How
Navigate to EMS Setup and locate the Export Endpoints configuration.
Ensure the applicable export endpoints are configured and active.
Verify that designated notification recipients are configured in EMS Contacts.
Ensure notification delivery settings are configured within General Settings and Notification Settings.
Configure failure notifications for each applicable export endpoint.
Designate the appropriate personnel to receive failure notifications.
Save the configuration to activate automated failure notifications.
Note: Each export endpoint is configured independently, allowing agencies to customize notification recipients based on the integration. Notification delivery utilizes the existing infrastructure shared by QA/QI, Outcome, and Incident List Notifications.
- Use Case – An EMS agency that exports ePCR data to both a billing platform and a state repository can configure separate failure notifications for each endpoint. If a billing export fails, designated billing personnel are automatically notified and can address the issue before it impacts revenue cycle timelines. Similarly, if a state repository export fails, designated administrative personnel can take corrective action without waiting for a manual audit to identify missing records.